MODEM-PT (Modem Pool Port)
Table 10-417. TEST #98 Modem Pool Conversion Resource Loop Around Test
Error
Code
5006
5007
5009
5010
5011
5012
555-233-123
— Continued
Test
Result
FIL
The Modem Pool Port did not respond to the "maintenance
activate" message. This error is internal to the Modem Pool
circuit pack and does not involve external equipment or
interfaces. The test failed. This error is internal to the Pooled
Modem circuit pack and does not involve external equipment
or interfaces.
1. Busyout both of the TN758 Pooled Modem conversion
resources on the circuit pack containing the failing
conversion resource.
2. If the test continues to fail, replace the Pooled Modem
circuit pack and retest.
3. If the circuit pack fails after replacement, escalate the
problem.
ABORT
The Network Control Channel allocated for this test did not
respond to the incoming call indication.
1. Follow the repair procedures for Error Code 5001.
ABORT
The Network Control Channel allocated for this test did not
handshake correctly.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack
using test data-module (refer to the DATA-CHL
maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the
trouble report.
FAIL
The Data Loop Around Test failed, indicating a probable
problem with the TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
ABORT
The Network Control Channel allocated for this test did not
disconnect properly.
1. Follow the repair procedures for Error Code 5001.
ABORT
The digital portion of the tested Modem Pool Port did not
disconnect properly.
1. Follow the repair procedures for Error Code 5000.
Description/Recommendation
Continued on next page