Analog I/O Option Mcb 109 - Danfoss VLT AQUA Drive FC 200 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

6 How to Programme the Low Harmonic Drive
Par.
Parameter description
No. #
25-8* Status
25-80
Cascade Status
25-81
Pump Status
25-82
Lead Pump
25-83
Relay Status
25-84
Pump ON Time
25-85
Relay ON Time
25-86
Reset Relay Counters
25-9* Service
25-90
Pump Interlock
25-91
Manual Alternation

6.4.22 Analog I/O Option MCB 109 26-**

Par.
Parameter description
6
No. #
26-0* Analog I/O Mode
26-00
Terminal X42/1 Mode
26-01
Terminal X42/3 Mode
26-02
Terminal X42/5 Mode
26-1* Analog Input X42/1
26-10
Terminal X42/1 Low Voltage
26-11
Terminal X42/1 High Voltage
26-14
Term. X42/1 Low Ref./Feedb. Value
26-15
Term. X42/1 High Ref./Feedb. Value
26-16
Term. X42/1 Filter Time Constant
26-17
Term. X42/1 Live Zero
26-2* Analog Input X42/3
26-20
Terminal X42/3 Low Voltage
26-21
Terminal X42/3 High Voltage
26-24
Term. X42/3 Low Ref./Feedb. Value
26-25
Term. X42/3 High Ref./Feedb. Value
26-26
Term. X42/3 Filter Time Constant
26-27
Term. X42/3 Live Zero
26-3* Analog Input X42/5
26-30
Terminal X42/5 Low Voltage
26-31
Terminal X42/5 High Voltage
26-34
Term. X42/5 Low Ref./Feedb. Value
26-35
Term. X42/5 High Ref./Feedb. Value
26-36
Term. X42/5 Filter Time Constant
26-37
Term. X42/5 Live Zero
26-4* Analog Out X42/7
26-40
Terminal X42/7 Output
26-41
Terminal X42/7 Min. Scale
26-42
Terminal X42/7 Max. Scale
26-43
Terminal X42/7 Bus Control
26-44
Terminal X42/7 Timeout Preset
26-5* Analog Out X42/9
26-50
Terminal X42/9 Output
26-51
Terminal X42/9 Min. Scale
26-52
Terminal X42/9 Max. Scale
26-53
Terminal X42/9 Bus Control
26-54
Terminal X42/9 Timeout Preset
26-6* Analog Out X42/11
26-60
Terminal X42/11 Output
26-61
Terminal X42/11 Min. Scale
26-62
Terminal X42/11 Max. Scale
26-63
Terminal X42/11 Bus Control
26-64
Terminal X42/11 Timeout Preset
142
VLT AQUA Low Harmonic Drive Operating In-
Default value
0 N/A
0 N/A
0 N/A
0 N/A
0 h
0 h
[0] Do not reset
[0] Off
0 N/A
Default value
[1] Voltage
[1] Voltage
[1] Voltage
0.07 V
10.00 V
0.000 N/A
100.000 N/A
0.001 s
[1] Enabled
0.07 V
10.00 V
0.000 N/A
100.000 N/A
0.001 s
[1] Enabled
0.07 V
10.00 V
0.000 N/A
100.000 N/A
0.001 s
[1] Enabled
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
®
MG.20.T1.02 - VLT
is a registered Danfoss trademark
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
74
All set-ups
TRUE
74
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
0
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
-2
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
-2
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
-2
structions
Type
VisStr[2
5]
VisStr[2
5]
Uint8
VisStr[4
]
Uint32
Uint32
Uint8
Uint8
Uint8
Type
Uint8
Uint8
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16