VACON · 344
The parameter is available for NXP drives only.
1288 GENERATOR TORQUE LIMIT 6 (2.6.21)
Use this parameter to set the maximum torque limit of the generating side.
The parameter is available for NXP drives only.
1289 MOTORING POWER LIMIT 6 (2.6.23.20)
Use this parameter to set the maximum power limit of the motoring side.
For Closed Loop control mode only.
1290 GENERATOR POWER LIMIT 6 (2.6.23.19)
Use this parameter to set the maximum power limit of the generating side.
For Closed Loop control mode only.
1316 BRAKE FAULT RESPONSE 6 (2.7.28)
Use this parameter to set the response type to a brake fault.
Table 206: Selections for parameter ID1316
Selection
number
0
No response
1
Warning
Fault, stop mode after fault
2
according to ID506
Fault, stop mode after fault
3
always by coasting
1317 BRAKE FAULT DELAYS 6 (2.7.29)
Use this parameter to set the delay after which the brake fault is activated when there is a
mechanical delay in the brake.
See parameter ID1210.
1324 MASTER/FOLLOWER SELECTION 6 (2.11.1)
Use this parameter to select the Master/Follower mode.
When the value Follower is selected the Run Request command is monitored from Master.
All other references are selectable by parameters.