PARAMETER DESCRIPTIONS
329 ANALOGUE INPUT 2 FILTER TIME 34567 (2.2.14, 2.2.26, 2.2.3.2)
Use this parameter to filter out disturbances in the analogue input signal.
See ID324.
330 DIN5 FUNCTION 5 (2.2.3)
Use this parameter to select the function for the digital input signal.
The digital input DIN5 has 14 possible functions. If it need not be used, set the value of this
parameter to 0.
The selections are the same as in parameter ID319 except:
13 Enable PID reference 2
Contact open: PID controller reference selected with parameter ID332.
Contact closed: PID controller keypad reference 2 selected with parameter R3.5.
331 MOTOR POTENTIOMETER RAMP TIME 3567 (2.2.22, 2.2.27, 2.2.1.2, 2.2.1.15)
Use this parameter to set the rate of change in the motor potentiometer reference when it is
increased or decreased.
Motor control ramp times are still active.
332 PID CONTROLLER REFERENCE SIGNAL (PLACE A) 57 (2.1.11)
Use this parameter to select the source of the PID controller signal.
Table 127: Selection for parameter ID332
Applic.
Sel.
0
1
2
PID ref. from menu M3, parameter P3.4
Fieldbus ref. (FBProcessDataIN1)
3
See Chapter 9.7 Fieldbus control parameters
4
Motor potentiometer reference
5
6
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
5
Analogue input 1
Analogue input 2
(IDs 850 to 859).
7
Analogue input 1
Analogue input 2
AI3
AI4
PID ref. from menu M3, parameter P3.4
Fieldbus ref. (FBProcessDataIN1)
See Chapter 9.7 Fieldbus control parameters (IDs
850 to 859).
Motor potentiometer reference
VACON · 243