PARAMETER DESCRIPTIONS
154 AI4 SIGNAL RANGE 567 (2.2.43, 2.2.5.3)
Use this parameter to change the range of the analogue signal.
See ID143.
155 AI4 CUSTOM SETTING MINIMUM 67 (2.2.5.3, 2.2.5.4)
Use this parameter to adjust the scaling of the analogue input signal between -160%...160%
freely.
156 AI4 CUSTOM SETTING MAXIMUM * 67 (2.2.5.4, 2.2.5.5)
Use this parameter to adjust the scaling of the analogue input signal between -160%...160%
freely.
See IDs 144 and 145.
162 AI4 SIGNAL INVERSION 567 (2.2.44, 2.2.5.5, 2.2.5.6)
Use this parameter to invert the analogue input signal.
See ID151.
164 MOTOR CONTROL MODE 1/2 6 (2.2.7.22)
Use this parameter to set the motor control mode 1 or 2.
Contact is open (oc) = Motor control mode 1 is selected
Contact is closed (cc) = Motor control mode 2 is selected
See parameter IDs 600 and 521.
Change from open loop to closed loop control modes and vice versa can only be made in stop
state.
165 AI1 JOYSTICK OFFSET 6 (2.2.2.11)
Use this parameter to set the frequency zero point. Find the parameter, set the
potentiometer at the assumed zero point and press Enter on the keypad.
NOTE!
This will not, however, change the reference scaling.
Press Reset button to change the parameter value back to 0.00%.
166 AI2 JOYSTICK OFFSET 6 (2.2.3.11)
Use this parameter to set the frequency zero point. Find the parameter, set the
potentiometer at the assumed zero point and press Enter on the keypad.
See parameter ID165.