VACON · 236
Table 122: Output signals via DO1 and output relays RO1 and RO2
Setting value
17 = External brake control (Appl. 3456)
18 = Control from I/O terminals (Appl.
3456)
19 = Frequency converter temperature
limit supervision (Appl. 3456)
20 = Unrequested rotation direction (Appl.
345)
20 = Reference inverted (Appl. 6)
21 = External brake control inverted
(Appl. 3456)
22 = Thermistor fault or warning (Appl.
3456)
23 = Fieldbus DIN1 (Application 5)
23 = Analogue input supervision (Applica-
tion 6)
24 = Fieldbus DIN1 (Application 6)
25 = Fieldbus DIN2 (Application 6)
26 = Fieldbus DIN3 (Application 6)
315 OUTPUT FREQUENCY LIMIT SUPERVISION FUNCTION 234567 (2.3.10, 2.3.4.1, 2.3.2.1)
Use this parameter to select the limit supervision function for the output frequency.
Table 123: Selections for parameter ID315
Selection
number
0
No supervision
1
Low limit supervision
2
High limit supervision
Brake-on control
3
If the output frequency goes under/over the set limit (ID316) this function generates a
message via digital output depending
9
External brake ON/OFF control with programmable delay (parame-
ters ID352 and ID353)
External control mode (Menu M3; ID125)
The AC drive heatsink temperature goes beyond the set supervision
limits (parameters ID354 and ID355).
Rotation direction is different from the requested one.
External brake ON/OFF control (parameters ID352 and ID353); Out-
put active when brake control is OFF
The thermistor input of option board indicates motor overtempera-
ture. Fault or warning depending on parameter ID732.
Fieldbus digital input 1. See fieldbus manual.
Selects the analogue input to be monitored. See parameters ID356,
ID357, ID358 and ID463.
Fieldbus digital input 1. See fieldbus manual.
Fieldbus digital input 2. See fieldbus manual.
Fieldbus digital input 3. See fieldbus manual.
Selection name
(Application 6 only, see Chapter 9.3 External brake control
with additional limits (IDs 315, 316, 346 to 349, 352, 353).)