Vacon NX Series Applications Manual page 134

Ac drives
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

VACON · 134
** = Apply the Terminal to Function method (TTF) to these parameters (see Chapter 9.9
"Terminal to function" (TTF) programming principle)
Table 60: Free analogue input, signal selection (Keypad: Menu M2 -> G2.2.6)
Index
Parameter
Scaling of current
P2.2.6.1
limit
Scaling of DC-
P2.2.6.2
braking current
Scaling of acc./
P2.2.6.3
dec. times
Scaling of torque
P2.2.6.4
supervision limit
Scaling of torque
P2.2.6.5
limit
NXP drives only
Scaling of genera-
P2.2.6.6
tor torque limit
Scaling of motor-
P2.2.6.7
ing power limit
Scaling of genera-
P2.2.6.8
tor power limit
Use TTF programming method for all Digital inputs parameters. See Chapter 9.9 "Terminal
to function" (TTF) programming principle
6
Min
Max
Unit
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
MULTI-PURPOSE CONTROL APPLICATION
Default
Cust
ID
0
399
0
400
0
401
0
402
0
485
0
1087
0
179
0
1088
Description
0 = Not used
1= AI1
2 = AI2
3 = AI3
4 = AI4
5 = FB Limit Scal-
ing See group G2.9
As parameter
P2.2.6.1 Scaling
from 0 to ID507.
As parameter
P2.2.6.1 Scales
active ramp from
100 % to 10 %.
As parameter
P2.2.6.1 Scaling
from 0 to ID348.
As parameter
P2.2.6.1 Scaling
from 0 to (ID609
(NXS) or ID1287
(NXP)).
As parameter
P2.2.6.1 Scaling
from 0 to ID1288.
As parameter
P2.2.6.1 Scaling
from 0 to ID1289.
As parameter
P2.2.6.1 Scaling
from 0 to ID1290.