Vacon NX Series Applications Manual page 149

Ac drives
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

MULTI-PURPOSE CONTROL APPLICATION
Table 71: Motor control parameters, G2.6
Index
Parameter
Speed controller P
P2.6.13
gain (open loop)
Speed controller I
P2.6.14
gain (open loop)
P2.6.15
Load drooping
P2.6.16
Identification
NXP drives only
P2.6.17
Restart delay
Load drooping
P2.6.18
time
Negative fre-
P2.6.19
quency limit
Positive frequency
P2.6.20
limit
Generator torque
P2.6.21
limit
Motoring torque
P2.6.22
limit
* = Parameter value can only be changed after the AC drive has been stopped.
NOTE!
Depending on the application version, the parameter code may appear as 2.6.17.xx
instead of 2.6.23.xx
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
Min
Max
Unit
0
32767
0
32767
0.00
100.00
%
0
1/4
0.100
60000
s
0
32000
ms
-327.67
P2.6.20
Hz
P2.6.19
327.67
Hz
0.0
300.0
%
0.0
300.0
%
Default
Cust
ID
3000
637
300
638
0.00
620
0
631
Varies
1424
0
656
-327.67
1286
327.67
1285
300.0
1288
300.0
1287
VACON · 149
Description
0 = No action
1 = Identification
w/o run
NXP:
2 = Identification
with run
3 = Encoder ID Run
(PMSM)
4 = Ident All
6