PARAMETER DESCRIPTIONS
Table 196: Selectable values for Actual Value Special Display
Value
27
28
29 *
* = Valid only for Application 5 (PID Control Application).
NOTE!
The maximum number of characters that can be shown on keypad is 4. This means
that in some cases the display of the unit on the keypad does not comply with the
standards.
Fig. 89: Display example
A. Actual value min (max)
1080 DC-BRAKE CURRENT AT STOP 6 (2.4.14)
Use this parameter to set the current fed to the motor in stop state when the DC braking is
active.
In the Multi-Purpose Control application, this parameter defines the current injected to the
motor in stop state when parameter ID416 is active. In all other applications this value is
fixed to a tenth of the DC brake current.
The parameter is available for NXP drives only.
1081 FOLLOWER REFERENCE SELECTION 6 (2.11.3)
Use this parameter to select the speed reference to the follower drive.
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
Unit
kW
Hp
Inch
A
B
B. Number of decimals
VACON · 335
On keypad
kW
Hp
Inch
9