VACON · 188
Table 94: Analogue output 1 (Control keypad: Menu M2 -> G2.3.3)
Index
Parameter
Analogue output 1
P2.3.3.1 *
signal selection
Analogue output
P2.3.3.2
function
Analogue output
P2.3.3.3
filter time
Analogue output
P2.3.3.4
inversion
Analogue output
P2.3.3.5
minimum
Analogue output
P2.3.3.6
scale
Analogue output
P2.3.3.7
offset
* = Use TTF method to program these parameters.
7
Min
Max
Unit
0.1
E.10
0
14
0.00
10.00
s
0
1
0
1
10
1000
%
-100.00
100.00
%
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
PUMP AND FAN CONTROL APPLICATION
Default
Cust
ID
A.1
464
1
307
1.00
308
0
309
0
310
100
311
0.00
375
Description
0 = Not used (20
mA / 10 V)
1 = Output freq. (0-
f
)
max
2 = Freq. reference
(0-f
)
max
3 = Motor speed
(0-Motor nominal
speed
4 = Motor current
(0-I
)
nMotor
5 = Motor torque
(0-T
)
nMotor
6 = Motor power
(0-P
)
nMotor
7 = Motor voltage
(0-U
)
nMotor
8 = DC link volt
(0-1000V)
9 = PID controller
ref. value
10 = PID contr.
act.value 1
11 = PID contr.
act.value 2
12 = PID contr.
error value
13 = PID controller
output
14 = PT100 tem-
perature
0 = No filtering
0 = Not inverted
1 = Inverted
0 = 0 mA (0 V)
1 = 4 mA (2 V)

Advertisement