VACON · 232
Fig. 37: Analogue output filtering
309 ANALOGUE OUTPUT INVERSION 234567 (2.3.4, 2.3.5.4, 2.3.3.4)
Use this parameter to invert the analogue output signal.
Maximum output signal = Minimum set value
Minimum output signal = Maximum set value
See parameter ID311 below.
Analog
output
current
20 mA
12 mA
10 mA
4 mA
0 mA
Fig. 38: Analogue output invert
310 ANALOGUE OUTPUT MINIMUM 234567 (2.3.5, 2.3.5.5, 2.3.3.5)
Use this parameter to set the minimum value of the analogue output signal.
9
%
Unfiltered signal
100%
63%
ID308
ID311 =
200%
0
0.5
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
PARAMETER DESCRIPTIONS
Filtered signal
ID311=
50%
ID311 =
100%
Max. value of signal
selected with ID307