Vacon NX Series Applications Manual page 242

Ac drives
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

VACON · 242
Table 126: Selections for parameter ID325
Applic.
3, 4
Sel.
0
0-20 mA
1
4-20 mA
2
Customised
3
326 ANALOGUE INPUT AI2 CUSTOM SETTING MIN. 34567 (2.2.11, 2.2.23, 2.2.3.4)
Use this parameter to adjust the minimum value of the analogue input signal between
-160%...160% freely.
327 ANALOGUE INPUT AI2 CUSTOM SETTING MAX. 34567 (2.2.12, 2.2.24, 2.2.3.5)
Use this parameter to adjust the maximum value of the analogue input signal between
-160%...160% freely.
See ID322.
Fig. 45: Analogue input AI2 scaling
328 ANALOGUE INPUT 2 INVERSION 3457 (2.2.13, 2.2.25, 2.2.3.6)
Use this parameter to invert the analogue input signal.
See ID323.
NOTE!
In application 3, AI2 is the place A frequency reference, if parameter ID117 = 1
(default)
9
5
0-20 mA
4 mA/20-100%
Customised
f
out
ID304
ID325 = Custom
ID325 = 0
AI2 = 0-100%
ID325 = 1
AI2 = 20-100%
ID303
4 mA
0
ID326
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
PARAMETER DESCRIPTIONS
6
0-100%
4 mA/20-100%
–10...+10 V
Customised
AI2
(term. 3,4)
ID327
20 mA
7
0-100%
4 mA/20-100%
Customised

Advertisement

Table of Contents
loading