VACON · 272
444 I/O CONTROL PLACE ACTIVE * 67 (2.3.3.13, 2.3.1.13)
Use this parameter to select a digital output for the external control place status.
445 EXTERNAL BRAKE CONTROL * 67 (2.3.3.14, 2.3.1.14)
Use this parameter to select a digital output for the external brake control status.
See Chapter 9.3 External brake control with additional limits (IDs 315, 316, 346 to 349, 352, 353)
for details.
Example: RO1 on OPTA2 board:
Brake function ON: Terminals 22-23 are closed (relay is energized).
Brake function OFF: Terminals 22-23 are open (relay not energized).
NOTE!
When power from control board is removed terminals 22-23 open.
When using the Master Follower function, the follower drive will open the brake at the same
time as the Master does even if the Follower's conditions for brake opening have not been
met.
446 EXTERNAL BRAKE CONTROL, INVERTED * 67 (2.3.3.15, 2.3.1.15)
Use this parameter to select a digital output for the external brake control inverted status.
See Chapter 9.3 External brake control with additional limits (IDs 315, 316, 346 to 349, 352, 353)
for details.
Example: RO1 on OPTA2 board:
Brake function ON: Terminals 22-23 are open (relay not energized).
Brake function OFF: Terminals 22-23 are closed (relay is energized).
When using the Master Follower function, the follower drive will open the brake at the same
time as the Master does even if the Follower's conditions for brake opening have not been
met.
447 OUTPUT FREQUENCY LIMIT 1 SUPERVISION * 67 (2.3.3.16, 2.3.1.16)
Use this parameter to select a digital output for the frequency output supervision 1 status.
The output frequency goes outside the set supervision low limit/high limit (see parameters
ID315 and ID316).
448 OUTPUT FREQUENCY LIMIT 2 SUPERVISION * 67 (2.3.3.17, 2.3.1.17)
Use this parameter to select a digital output for the frequency output supervision 2 status.
The output frequency goes outside the set supervision low limit/high limit (see parameters
ID346 and ID347).
9
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
PARAMETER DESCRIPTIONS