Vacon NX Series Applications Manual page 142

Ac drives
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

VACON · 142
Table 65: Limit settings (Control keypad: Menu M2 -> G2.3.4)
Index
Parameter
Temperature limit
P2.3.4.11
supervision
Temperature
P2.3.4.12
supervised value
Analogue supervi-
P2.3.4.13
sion signal
Analogue supervi-
P2.3.4.14
sion low limit
Analogue supervi-
P2.3.4.15
sion high limit
NXP drives only
Brake On/Off Cur-
P2.3.4.16
rent Limit
6
Min
Max
Unit
0
2
-10
100
°C
0
4
0.00
100.00
%
0.00
100.00
%
0
2 x I
A
H
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
MULTI-PURPOSE CONTROL APPLICATION
Default
Cust
ID
0
354
40
355
0
356
10.00
357
90.00
358
0
1085
Description
0 = No supervision
1 = Low limit
2 = High limit
0 = Not used
1 = AI1
2 = AI2
3 = AI3
4 = AI4
See P2.3.3.22.
See P2.3.3.22.

Advertisement

Table of Contents
loading

Table of Contents