VACON · 134
Table 34: Frequency reference parameters
Index
Parameter
Keypad Control Ref-
P3.3.1.7
erence Selection
P3.3.1.8
Keypad Reference
P3.3.1.9
Keypad Direction
Fieldbus Control
P3.3.1.10
Reference Selection
* = The selection of the application with parameter P1.2 Application gives the default value.
See the default values in Chapter 12.1 The default values of parameters in the different
applications.
5
Min
Max
Unit
0
20
0.00
P3.3.1.2.
Hz
0
1
0
20
LOCAL CONTACTS: HTTP://DRIVES.DANFOSS.COM/DANFOSS-DRIVES/LOCAL-CONTACTS/
PARAMETERS MENU
Default
ID
Description
0 = PC
1 = Preset frequency 0
2 = Keypad reference
3 = Fieldbus
4 = AI1
5 = AI2
6 = AI1+AI2
7 = PID
8 = Motor potentiome-
ter
1 *
121
11 = Block Out.1
12 = Block Out.2
13 = Block Out.3
14 = Block Out.4
15 = Block Out.5
16 = Block Out.6
17 = Block Out.7
18 = Block Out.8
19 = Block Out.9
20 = Block Out.10
0.00
184
0 = Forward
0
123
1 = Reverse
0 = PC
1 = Preset frequency 0
2 = Keypad reference
3 = Fieldbus
4 = AI1
5 = AI2
6 = AI1+AI2
7 = PID
8 = Motor potentiome-
ter
2 *
122
11 = Block Out.1
12 = Block Out.2
13 = Block Out.3
14 = Block Out.4
15 = Block Out.5
16 = Block Out.6
17 = Block Out.7
18 = Block Out.8
19 = Block Out.9
20 = Block Out.10