Delete Data Collection; Maintenance - HPE StoreOnce 6500 User Manual

Table of Contents

Advertisement

IMPORTANT:
If using Internet Explorer as the web browser, verify the following Security configuration options are
set. If not, the download will not work as expected and there will be no error message.
1. Add https://VIF , https://node1 , https://node2
2. Enable download.
Other browsers, such as Mozilla Firefox and Google Chrome process the download correctly,
without further configuration.

Delete data collection

Use the Delete button to delete the selected data collections, or Delete All to remove all data collections.
This operation removes the tar files on each node from the system.
NOTE:
This operation may take some time.
The equivalent CLI command is support del ticket and is accessible to both administrators and
operators.

Maintenance

The Maintenance page provides the ability to shut down or reboot the system hardware.
This page is also used to enable or disable failover.
Enable Failover: Enables failover on all of the nodes within the cluster. This function is the same as
using the CLI system enable failovercommand.
This button is inactive if failover is already enabled on all nodes. If some nodes are enabled and some
are disabled, the Enable Failover button is active and will act to enable failover on all of the nodes.
NOTE: During normal use, failover should always be enabled for all nodes or the cluster is not resilient
to hardware failures affecting a node. The status of failover for each service set can be seen on the
GUI. If any nodes have failover disabled, use the Enable Failover button to enable failover on those
nodes.
Disable Failover: Disables failover on all of the nodes within the cluster. This function is the same as
using the CLI system disable failover command.
This button is inactive if failover is already disabled on all nodes. If some nodes are enabled and some
are disabled, the Disable Failover button is active and will disable failover on all of the nodes.
Shutdown: Shuts down the StoreOnce appliance. Storage enclosures, switches, and other hardware
components are not affected and must be powered off manually after shutting down the StoreOnce
server node. This function is the same as using the CLI system shutdown command.
Delete data collection