Monitoring Switches - HPE StoreOnce 6500 User Manual

Table of Contents

Advertisement

Name
Network Bonds
Power Management
Controllers
Power Supplies
Server Storage
Storage Controller (PCI
Slot n)
Storage Controller (PCI
Slot n)
Temperature sensors
VLAN
Differences between systems
The number of NIC and HBA entries will vary depending on the installed optional hardware.
VIF appears on StoreOnce 6500 and 6600 systems only: It provides the IP address of virtual
interfaces associated with the selected server node

Monitoring switches

There is an entry for each switch that contains the IP address of the switch. The following installed
hardware components are included under the tree hierarchy for each switch:
Fan: The status of the two fans within the switch
Power supply: The status of the two power supplies for each switch, each has its own entry
Temperature sensors: The status of temperature sensors of the switch
Description
Shows all available bonds
The PMCs perform the powering up and powering down of the processor
Power supplies for the appliance
These are the disks within the head server that contain the operating and file
system; for most models, these disks are not used for data storage. Expand
to see status information about the disks under Drive Enclosure, RAID
information under Pool and Volumes, and the Storage Controller which is the
P420 Smart Array on the motherboard.
This is the first RAID controller card and the slot location where it is installed.
The Name and UUID information is used to map the storage controller to the
appropriate drawer/disk enclosure in the Storage Clusters section of the
Hardware tree. This entry also contains information about the status of the
cache module and super capacitor and the SAS ports on this RAID controller
card that connect to the drawer in the disk enclosure.
This is the second RAID controller card and the slot location where it is
installed. The Name and UUID information is used to map the storage
controller to the appropriate disk enclosure in the Storage Clusters section of
the Hardware tree. This entry also contains information about the status of
the cache module and super capacitor and the SAS ports on this RAID
controller card that connect to the drawer in the disk enclosure.
NOTE: Not all models have two RAID controllers.
Provide temperature monitoring
If VLAN subnets have been configured on the system, the VLAN tags that
have been used are listed here.
Monitoring switches
125