Source Appliances Tab - HPE StoreOnce 6500 User Manual

Table of Contents

Advertisement

Blackout Window Active
Blackout Windows
To add a target appliance (administrators only)
Click Add Target Appliance.
Enter the Target Appliance Address.
NOTE: If the Target Appliance is on a 6500 and 6600 System, enter the Data VIF IP address of the
required Service Set. See Identifying the appliance Data VIF IP address .
The default values for the Command and Data Protocol Port Numbers cannot be changed. If
replication needs to take place through a firewall, the network administrator must open (TCP) ports
9387 (Command Protocol) and 9388 (Data Protocol).
Click Add Target Appliance.
To edit or remove a Target Appliance (administrators only)
Select the appliance and click Edit to edit the Appliance Name, IP address, and protocol port details of
the target appliance.
Select the appliance and click Delete to remove an appliance from the list of Target Appliances
available to that source.
Run Traceroute
Click Run Traceroute to verify the local appliance can communicate with the target appliance and identify
the number of hops and latency in the routing.

Source Appliances tab

This tab displays the details of all source appliances.
If the StoreOnce System also has Replication Target libraries, there may be multiple Source Appliances.
NOTE: Source Appliances are appliances that have added the local appliance or Service Set as a Target
Appliance. Only Source Appliances currently connected to the Target Appliance are listed.
The Source Appliances tab is not editable.
58
Source Appliances tab
Shows whether a blackout window is currently active or not. This means
that no replication will occur.
Any blackout windows that have been specified will be reflected in this
weekly calendar. During these times, the selected Target Appliance is not
available for replication. Administrators may edit and delete blackout
windows from here or from the Local Settings tab.
NOTE: If you set an End of Restriction blackout window to 23.59, the
blackout window will last until the end of the day (meaning, the window
will end at 23.59.59).