HPE StoreOnce 6500 User Manual page 61

Table of Contents

Advertisement

Procedure
1. Select the General Settings tab.
2. Click Edit to make the fields editable.
3. Edit the fields as needed.
Table 17: General Settings (Replication)
Appliance
Maximum Jobs
Synchronization Progress
Logging
Out of Sync Notification
Settings
Configure Replication Ports Only change replication ports if replication is blocked by a router on the
4. Click Apply to apply the settings.
The name of the appliance, its current status, and the product class.
You can only edit the appliance name. The default name is the network
host name of the appliance (as configured at installation). You can
change this to something more user-friendly and easier to identify the
appliance on the Management Console of the local and partner
appliances. The name can be anything meaningful to the user, such as
the geographical location of the appliance. The Appliance Supported
Protocol Version shows which versions of replication protocol are
supported, so in the unlikely event of incompatible versions it will be
visible to the user. Replication auto negotiates to the lowest supported
protocol on either end.
The maximum number of source and target jobs that can run
concurrently. If running backups at the same time as replication, the
default value of target jobs can be reduced to avoid using too much
WAN bandwidth and overloading the target appliance and reserve
appliance performance.
An event is generated each time a mapping goes out of sync and goes
back into sync. This field applies to periodic sync progress updates
while the mapping remains out of sync resulting in emails (if emails are
configured) but not SNMP traps. Use these fields to enable progress
logging for Library and Share synchronization and to specify the
logging interval. While the library or share is out of sync, emails are
sent periodically indicating how many slots or entries are still out of
sync. This information is also logged to the user Event Log. One email
is sent for each log entry made for each library or share that is out of
sync.
Use these fields to specify the amount of time a mapping needs to be
out of sync before a sync issue is shown in the Issue tab. When an
event is generated it results in an entry in the user Event Log and an
email and/or an SNMP trap if the appliance is configured to send these.
These notifications are in addition to a standard notification email sent
whenever a mapping first becomes unsynchronized and another when
synchronization is achieved.
WAN. The ports must be the same on both source and target
appliances. If in doubt, do NOT change the port configuration.
Replication functions
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storeonce 6600

Table of Contents