HPE StoreOnce 6500 User Manual page 128

Table of Contents

Advertisement

Table 42: File system status and recommended actions
Status
Mounted
Not Mounted
Segments On Backup
Space Over
Segment Unavailable
128
Storage configuration and reporting
Description
The file system is up and
running.
The file system is not up and
running, resulting in the service
sets not starting.
The file system is in a failed over
state and some of the storage is
owned by its failover node.
Some or all of the storage
components have reached 90%
capacity utilization.
Some or all of the storage
components have detected a
problem. The file system is set to
read-only mode to prevent further
problems.
Recommended Actions
None required.
This is expected during upgrades
or during the power on sequence.
If the file system status is
Unmounted at any other time,
reboot the appliance or couplet.
If this does not resolve issue,
contact Hewlett Packard
Enterprise Support.
This may be as intended or as a
result of a failure condition.
Check and resolve any issues
shown in the Events Log. To
failback, run the StoreOnce CLI
command system failback
[specified service set].
This may be temporary or
showing that the specified file
system is approaching its
capacity. Check the Events Log
to see whether the file system is
reaching capacity. If so, increase
storage capacity or delete data
from the file system to prevent
backup failure.
This is due to the storage
subsystem unexpectedly going
offline. Check if the storage
subsystem is online and then run
the StoreOnce CLI command
system recover
filesystem. If the issue
persists, contact Hewlett Packard
Enterprise Support.
Table Continued

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storeonce 6600

Table of Contents