11
FUNCTIONS OF CONFIGURATION TOOL (MODULE SETTINGS)

11.5.11 Trigger (compound condition)

This section explains the method for specifying a combination of multiple trigger conditions
when the logging type is specified as "Trigger logging".
For details on processes of each trigger (compound condition), refer to the following
section.
 Section 7.3.3 (2) Compound conditions
OR combine
AND combine
Number of times
Order
11
- 107
11.5 Data Logging Setting
11.5.11 Trigger (compound condition)
Operating procedure
Select "Compound condition".
Setting screen
Item
The trigger occurs when any of the conditions specified on the list of
conditions are established.
The trigger occurs during the period when all of the conditions specified
on the list of conditions are established.
The trigger occurs by monitoring the number of times the condition is
established.
The trigger occurs by monitoring the order the conditions are established.
Description
Reference
(1) in this
section
(2) in this
section
(3) in this
section
(4) in this
section
(Continued on the next page)