11
FUNCTIONS OF CONFIGURATION TOOL (MODULE SETTINGS)
[Number of records in layout is fewer than that in the source files]
40records
worth of
data are
not output
40records
[When the creation trigger executes immediately after the output target data logging file is
switched]
100records
When the specified number of records is 40, 30 records worth of data from the
storing file and 10 records worth of data from the latest saved file are output to the
report file.
(The remaining older 40 records worth of data in the latest saved file are not output.)
Report layout
50records
30records
When the creation trigger executes immediately after the output target data logging
file is switched, an unintended operation may occur due to the storing file which only
has a header or too few number of records.
For example, when "At the time of the data logging file is switched" is selected as the
creation trigger, only a header or one record worth of data may exist in the storing
file. Therefore, no record or only one record may output when the source file is set to
'Storing file'.
Adjust the system so the creation trigger executes with the necessary number of
records worth of data.
Report layout
Storing file
File output
Storing file
Latest saved file
30records
50records
Sample.BIN
00000002.BIN
File output
Storing file
Latest saved file
Header only
30records
or one record
Sample.BIN
00000002.BIN
11.7 Report Setting
11.7.5 Layout setting
10
Saved files
11
00000001.BIN
12
13
14
Saved files
50records
15
00000001.BIN
16
11
- 210