7
DATA LOGGING FUNCTION
(1) When all periods are combined with OR
(2) When all periods are combined with AND
7
- 17
7.4 Data Logging Periods
period 1
period 2
period 3
period 1
period 2
period 3
POINT
(1) If the data sampling interval is high speed data sampling, a maximum of 4
types of periods can be combined.
(2) When specifying combinations of periods, a combination of AND and OR
cannot be specified.
True
False
True
False
True
False
Processing period
True
False
True
False
True
False
Processing period