Mitsubishi Electric QJ81DL96 User Manual page 318

Melsec q series, high speed data logger module
Table of Contents

Advertisement

11
FUNCTIONS OF CONFIGURATION TOOL (MODULE SETTINGS)
11
- 73
11.4 Common Setting
11.4.7 Auto logging setting
POINT
(1) CF LED turns OFF when the CompactFlash card is ready to be ejected.
(2) Be aware of the following points when starting (power ON or resetting the
programmable controller CPU) the high speed data logger module without an
inserted CompactFlash card in order to use the auto logging function.
• Do not connect the high speed data logger module to a LAN line.
• In the data logging setting, event logging setting, and report setting, do
not configure them to perform FTP transfers or e-mail transmissions.
• The high speed data logger module operates with the factory default IP
address (192.168.3.3).
(3) To connect the Configuration Tool using the auto logging function, follow the
instructions below.
 Section 2.1.2 System configuration when performing initial setup,
maintenance, and inspection
(4) When specifying "Stop effected by a timer" of the auto logging setting, set the
elapsed time more than five seconds longer than the period of logging time.
When module operation stops, unprocessed data ( Section 3.4.11 (5) (g))
are not logged.