10
OTHER FUNCTIONS
The following figure shows the procedure for using the auto logging function.
Before executing the auto logging function, refer to Section 11.4.7 and configure the auto
logging settings using the Configuration Tool.
Write the auto logging setting to the inserted CompactFlash card
Eject the CompactFlash card from the personal computer
Insert the CompactFlash card into the high speed data logger module
Eject the CompactFlash card from the high speed data logger module
Start
Insert the CompactFlash card in a personal computer
The CF LED on the high speed data logger
module turns ON and auto logging starts
Does auto logging stop
automatically?
The CF LED on the high speed data logger
module turns OFF and auto logging stops
Complete
POINT
(1) For the auto logging settings, refer to the following section.
 Section 11.4.7 Auto logging setting
(2) To forcibly terminate auto logging, turn ON file access stop request (Y2) or
stop the CompactFlash card with the Configuration Tool.
(3) For operations to stop the CompactFlash card, refer to the following section.
 Section 13.1.6 CompactFlash card diagnostics
NO
YES
10.2 Auto Logging Function
 Section 11.3.6
Turn file access stop
request (Y2) ON
10
- 6
9
10
11
12
13
14
15
16