Mitsubishi Electric QJ81DL96 User Manual page 678

Melsec q series, high speed data logger module
Table of Contents

Advertisement

APPENDIX
Item
Reports are generated
during the period of time
which meets specified
conditions. /Reports are
PRDTYPE
not generated during the
period of time which
meets specified
conditions.
Conditions for
PRDCOMB
combination
Start of the array area
[PRDCOND_START]
(period of time and
condition)
Period of time and
((Array area))
condition
End of the array area
[PRDCOND_END]
(period of time and
condition)
SAVDEST
File save destination
SAVNAMETYPE
Saved file name setting
SAVNAMESIMPNAM
Attach the name
E
SAVNAMESIMPDATE Attach the date
SAVNAMESIMPTIME Attach the time
SAVNAMEDETLFRM
Format
T
SAVNAMEDETLDAT
Attached data setting
A1
<DATA1>
SAVNAMEDETLDAT
Attached data setting
A2
<DATA2>
SAVFNUM
Number of saved files
Operation occurring when
SAVFNUMTYPE
number of saved files is
exceeded
Transfer files to the
SAVFTPT
following FTP server
App
- 61
Appendix 10 Setting information CSV File Format
Setting
Reports are generated during the
period of time which meets specified
conditions.
Reports are not generated during the
period of time which meets specified
conditions.
Specify "AND"
Specify "OR"
-
When PRD is "YES"
-
-
Specify "Simple setting"
Specify "Detailed setting"
Turn on the checkbox
Turn off the checkbox
Turn on the checkbox
Turn off the checkbox
Turn on the checkbox
Turn off the checkbox
When SAVNAMETYPE is
"DETAILED"
Turn on the checkbox
Turn off the checkbox
Turn on the checkbox
Turn off the checkbox
-
Specify "Overwrite"
Specify "Stop"
Turn on the checkbox
Turn off the checkbox
Description
NOTCARRYOUT
PERIODOFTIME
(From the previous page)
Setting value
Remarks
CARRYOUT
This item is not applied in
the following situation.
• PRD is "NO"
AND
OR
(blank)
This item is not applied in
the following situation.
Refer to (k)
• PRD is "NO"
CONDITION
(blank)
String
SIMPLE
DETAILED
YES
This item is not applied in
the following situation.
NO
• SAVNAMETYPE is
"DETAILED"
YES
This item is not applied in
the following situation.
NO
• SAVNAMETYPE is
"DETAILED"
YES
This item is not applied in
the following situation.
NO
• SAVNAMETYPE is
"DETAILED"
This item is not applied in
the following situation.
String
• SAVNAMETYPE is
"SIMPLE"
001 to 256,
This item is not applied in
*001 to *256
the following situation.
• SAVNAMETYPE is
NO
"SIMPLE"
001 to 256,
This item is not applied in
*001 to *256
the following situation.
• SAVNAMETYPE is
NO
"SIMPLE"
1 to 65535
OVERWRITE
STOP
YES
NO
(Continued on the next page)
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnn-dlutl-e

Table of Contents