Time Synchronization Setting - Mitsubishi Electric QJ81DL96 User Manual

Melsec q series, high speed data logger module
Table of Contents

Advertisement

11
FUNCTIONS OF CONFIGURATION TOOL (MODULE SETTINGS)

11.4.2 Time synchronization setting

This section explains the settings for synchronizing the time used by the high speed data
logger module to a SNTP server computer on the network or the programmable controller
CPU (CPU No. 1 in a multiple CPU system).
Operating procedure
Setting screen
Item
Method of synchronization
PLC CPU synchronization
Synchronize with SNTP
SNTP server address
Time zone
Daylight saving setting
Synchronization timing
Click "Common setting" on the edit items tree of the Configuration Tool,
then click the
Select the equipment with which the time of high speed data logger module is
synchronized.
Select this to synchronize with the time of the programmable controller CPU.
For a multiple CPU system, synchronizes with programmable controller CPU No. 1.
Select this to synchronize with the time of the SNTP server computer.
Set the IP address of the SNTP server in decimal notation.
Select the time zone used for time synchronization.
Set the period which requires adjustment of the daylight saving time.
Set the timing to perform time synchronization.
*1: NTP servers can also be used.
button.
Description
*1
11.4 Common Setting
11.4.2 Time synchronization setting
9
10
11
12
13
Reference
-
14
(3), (4) in this
section
(3), (5) in this
section
-
-
15
(1) in this
section
(2) in this
section
16
11
- 40