E-Mail Send Diagnostics - Mitsubishi Electric QJ81DL96 User Manual

Melsec q series, high speed data logger module
Table of Contents

Advertisement

13
FUNCTIONS OF CONFIGURATION TOOL (CONFIRMING MODULE OPERATION)

13.1.4 E-mail send diagnostics

Monitors the results of sending e-mails.
Normal end
Error end
Error code
E-mail resending buffering status
Buffering Number
Buffer usage rate
13
- 7
13.1 Diagnostics
13.1.4 E-mail send diagnostics
Operating procedure
 Select [Online] [Diagnostics].
 Select the <<E-mail send diagnostics>> tab.
Screen display
Item
Displays the number of times that sending e-mail with the high speed data logger
module completed normally.
Displays the number of times that sending e-mail with the high speed data logger
module completed in an error.
Displays the newest error code of the e-mail transmission.
 Section 18.2 Error Code List
*1*2
Displays the number of data stored in the E-mail resend buffer memory.
Current value
*3
Maximum value : The maximum number of buffered data up to the present/Set
Displays the usage rate of the E-mail resend buffer memory.
*3
Current value
Maximum value : The maximum usage rate up to the present
Clears the FTP resend buffer memory and cancels resending the E-mail transfer.
button
*1: The FTP resend function is supported by the high speed data logger module with a serial number
whose first five digits are '12062' or higher only. "-" is displayed for unsupported modules.
*2: "-" is displayed when "Resend when sending failed" is not set in the optional setting of the E-mail
setting.
*3: The maximum value is cleared when the high speed data logger module is turned OFF.
Description
-
: Current number of buffered data/Set number of buffered data
number of buffering data
: Current usage rate

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnn-dlutl-e

Table of Contents