FUNCTIONS OF CONFIGURATION TOOL (MODULE SETTINGS)
(4) Network diagnostics setting
Item
Execute network diagnostics (ping)
Sending interval [Second](10-3600)
Destination
Gateway
Following external device
(External device)
11
- 39
11.4 Common Setting
11.4.1 Network setting
Set the network diagnostics (ping) settings to diagnose the network connection status
with the server device.
Setting screen
If this setting is enabled, a ping packet (1 packet) is transmitted regularly to perform network
*1
diagnostics.
If enabled, set the transmission interval and destination.
Set the ping packet transmission interval.
Set the ping packet destination.
Select this to send a ping packet to the gateway.
Select this to send a ping packet to the specified external device.
Specify the IP address or host name. (Up to 32 characters)
*1: When there is no response from the destination within 5 seconds, retries once. If there is still no
response after that, the module error occurs.
*2: Set the transmission interval considering the load on the network.