18
TROUBLESHOOTING
Error code
Incorrect device value
0C1C
H
error
Incorrect device value
0C1D
H
error
Incorrect device value
0C1E
H
error
Incorrect device value
0C1F
H
error
Incorrect device value
0C20
H
error
0C21
Incorrect attribute error
H
0C22
Incorrect attribute error
H
Incorrect device value
0C23
H
error
0C24
Incorrect data type error
H
0C25
No authority error
H
CompactFlash card
0C26
H
access error
0C27
Module suspension error
H
0C28
File size error
H
0C29
Module suspension error
H
Recipe execution
0C2A
H
operation error
Incorrect operation type
0C2B
H
error
0C2C
Module suspension error
H
18
- 27
18.2 Error Code List
Error name
A value out of the range is specified for the
data type "FLOAT [double precision]".
A value out of the range is specified for the
data type "Double word [unsigned]".
A value out of the range is specified for the
data type "Word [signed]".
A value out of the range is specified for the
data type "FLOAT [single precision]".
A value out of the range is specified for the
data type "Word [unsigned]".
The write process is performed on the
record with P attribute.
The read process is performed on the
record with N attribute.
A record number whose device value cell
is blank is specified.
"Bit" is specified for the data type of word
device.
The recipe execution operation was
performed by a user who does not have a
administrator's authority.
The access to the CompactFlash card was
attempted when the file access was being
stopped.
The recipe execution operation was
performed when the module suspended
error is being occurred.
A recipe file whose file size is 0 is
specified.
The recipe execution operation was
performed when the operation of high
speed data logger module was being
suspended.
The recipe execution operation is already
being performed.
An incompatible recipe execution
operation type is specified.
The recipe execution operation was
performed when the operation of high
speed data logger module was being
suspended.
Description
(From the previous page)
Action
• Specify a value within the range of
"FLOAT [double precision]" for the
device value.
• Specify a value within the range of
"Double word [unsigned]" for the device
value.
• Specify a value within the range of
"Word [signed]" for the device value.
• Specify a value within the range of
"FLOAT [single precision]" for the device
value.
• Specify a value within the range of
"Word [unsigned]" for the device value.
• Check the specified record number.
• Check the specified recipe file name.
• Check the specified recipe file.
• Check the specified record number.
• Check the specified recipe file name.
• Check the specified recipe file.
• Check the device value of the specified
record number.
• Check the data type of the recipe file.
• Retry with a user who has an
administrator's authority.
• Uncheck "Use the access authentication
function" in the Account setting.
• Check if a CompactFlash card is
inserted.
• Execute "Access restart" and retry.
 Section 13.1.6 CompactFlash card
diagnostics
• Turn the clear file access stop request
(Y3) ON, and retry after the file access
status (X2) is turned OFF.
• Remove the module suspended error
factor, reset the CPU module, and retry.
• Check the specified recipe file.
• Change the operating status of the
module to "In operation".
 Section 13.1.6 CompactFlash card
diagnostics
• Retry after the recipe execution
operation is completed.
• Correct the control data of the
RCPREAD instruction.
 Section 15.6.1 Recipe read
(RCPREAD)
• Change the operating status of the
module to "In operation".
 Section 13.1.6 CompactFlash card
diagnostics
(Continued on the next page)