Mitsubishi Electric QJ81DL96 User Manual page 597

Melsec q series, high speed data logger module
Table of Contents

Advertisement

18
TROUBLESHOOTING
Error code
0C60
Module suspension error
H
0C61
Module suspension error
H
0C62
Module suspension error
H
Recipe execution
0C63
H
operation error
0C64
H
CompactFlash card
to
access error
0C65
H
0C66
File size error
H
0C67
H
to
Module suspension error
0C68
H
0C69
H
to
Recipe file error
0C6A
H
0C6C
Number of blocks error
H
0C6D
Device error
H
0C6E
H
to
Incorrect data type error
0C6F
H
0C70
Number of records error
H
0C71
Number of data error
H
0C72
Number of blocks error
H
0C73
Number of records error
H
Error name
The recipe execution operation was
performed when the operation of high
speed data logger module was being
suspended.
The recipe execution operation was
performed when the module suspended
error is being occurred.
The recipe execution operation was
performed when the settings are being
updated.
Or the access to the CompactFlash card
was attempted while it is being formatted.
The recipe execution operation was
performed when the recipe execution
operation was already being performed.
The access to the CompactFlash card was
attempted when the file access was being
stopped.
A recipe file whose file size is 0 is
specified.
The recipe execution operation was
performed when the operation of high
speed data logger module was being
suspended.
The recipe file is not correctly formatted,
or corrupted recipe file is specified.
Insufficient number of blocks against
specified number of blocks.
An incorrect device is specified.
A data type that cannot be used for digit
specified bit device is specified.
Insufficient number of records against
specified number of records.
The cell for the number of data is blank.
The cell for the number of blocks is blank.
The cell for the number of records is blank.
Description
• Execute "Restart" of "Module operation"
and retry.
 Section 13.1.6 CompactFlash card
diagnostics
• Execute "Update settings" of "Module
operation" and retry.
 Section 13.1.6 CompactFlash card
diagnostics
• Remove the module suspended error
factor, reset the CPU module, and retry.
• Retry after the operating status of the
module is changed to "In operation".
 Section 13.1.6 CompactFlash card
diagnostics
• After formatting the CompactFlash card,
store recipe files to the CompactFlash
card, and retry.
• Retry after the recipe execution
operation is completed.
• Check if a CompactFlash card is
inserted.
• Execute "Access restart" and retry.
 Section 13.1.6 CompactFlash card
diagnostics
• Turn the clear file access stop request
(Y3) ON, and retry after the file access
status (X2) is turned OFF.
• Check the specified recipe file.
• Change the operating status of the
module to "In operation".
 Section 13.1.6 CompactFlash card
diagnostics
• Check the format of the specified recipe
file.
 Section 3.8 Recipe File Format
• Check the blocks and the number of
blocks for recipe files.
• Check the device of the specified recipe
file.
• Check the data type of the recipe file.
 Section 3.8 Recipe File Format
• Check the records and the number of
records for recipe files.
• Check the number of data.
• Check the number of blocks.
 Section 3.8 Recipe File Format
• Check the number of records.
 Section 3.8 Recipe File Format
18.2 Error Code List
(From the previous page)
Action
(Continued on the next page)