16
CompactFlash CARD
(1) Stopping file access
(2) Clearing file access stop
(a) When using the input signal
 Stopping file access.
Turn file access stop request (Y2) ON from OFF.
 Checking that file access has stopped.
• CompactFlash card status (X1) is OFF
• File access status (X2) is ON
• Turn file access stop request (Y2) OFF from ON
File access stop request (Y2)
File access status (X2)
CompactFlash card status (X1)
(b) When using the Configuration Tool ( Section 13.1.6 CompactFlash card
diagnostics)
 Stopping file access.
Select [Online] [Diagnostics...], and click the <<CompactFlash card
diagnostics>> tab. Then select CompactFlash card operation "Access stop"
and click the
 Checking that file access has stopped.
Check that the access status is stopped
(a) When using the input signal
 Clearing the file access stop status.
Turn clear file access stop request (Y3) ON from OFF
 Checking that file access stop status has cleared.
• CompactFlash card status (X1) is ON
• File access status (X2) is OFF
• Turn clear file access stop request (Y3) OFF from ON
Clear file access stop request (Y3)
File access status (X2)
CompactFlash card status (X1)
16.6 Operations for Replacing New CompactFlash Card
(Operating)
(Stopped)
button