Mitsubishi Electric QJ81DL96 User Manual page 156

Melsec q series, high speed data logger module
Table of Contents

Advertisement

4
SETTINGS AND PROCEDURES UP TO OPERATION
Name
Indicator LED
10BASE-T/100BASE-TX
Interface connector (RJ45)
Serial number indication plate Indicates the serial number of QD81DL96.
EJECT button
CompactFlash card slot
CompactFlash card slot cover Cover for the CompactFlash card slot
(3) Indicator LED display
RUN
ERR.
CF
100M
SD/RD
4
- 11
4.3 Parts Names
Refer to the indicator LED display ( (3) in this section)
A connector to connect the high speed data logger module to the 10BASE-T/100BASE-TX.
(The high speed data logger module distinguishes 10BASE-T from 100BASE-TX according to the
external device.)
This button ejects the CompactFlash card from the high speed data logger module.
Slot to insert the CompactFlash card into the high speed data logger module.
*1: A battery is not used with the high speed data logger module.
QD81DL96
Name
LED status
ON
Module operating normally
• Power OFF status
OFF
• Watchdog timer error (hardware failure)
Checking module
Flashing
(Flashes for 10 seconds when the
High Speed Data Logger Module" screen of the Configuration Tool or GX LogViewer.)
OFF
Status normal
ON
Module continuation error
Flashing
Module stop error
ON
CompactFlash card accessible status
OFF
CompactFlash card inaccessible status (ejectable status)
Flashing
Preparing CompactFlash card
ON
100Mbps
OFF
10Mbps
ON
Sending or receiving data
OFF
Not transmitting data
*2: Since the module performs a diagnostics of the CompactFlash card at startup, it may take some
time until the CF LED illuminates. ( Section 16.3 (6) CompactFlash card diagnostic time)
Description
RUN
ERR.
CF
*2
10BASE-T/
100BASE-TX
100
M
SD/
RD
Description
button is pressed on the "Find

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnn-dlutl-e

Table of Contents