SETTINGS AND PROCEDURES UP TO OPERATION
(4) Compatibility setting (Switch 4)
b15
* If this area is a value other than 0,
it will cause a switch setting error (0180
during hardware testing.
4
- 17
4.5 Intelligent Function Module Switch Setting
Set this switch to make the process, which may differ depending on a function version
(the first five digits of the serial number), the same as that on another function version
(the first five digits of the serial number).
For details of functions whose operations differ, refer to the following section.
 Appendix 8 Process Modifications
b3 b2 b1 b0
to
Specify 0.*
)
H
Compatibility setting (File switching timing)
0: The module operates as the module with a serial
number whose first 5 digits are '11102' or higher.
1: The module operates as the module with a serial
number whose first 5 digits are '11101' or lower.