Network Settings for 1:1 Connection

When connecting a development environment (personal computer) to a C Controller
module, connect them on one-to-one (1:1) basis by using an Ethernet cable.
After connection with an Ethernet cable, configure the settings of the C Controller module
from C Controller setting utility on the development environment (personal computer).
This section describes the network settings on the personal computer for 1:1 connection
between the C Controller module (CH1) and the development environment (personal
computer).
(1) System configuration for 1:1 connection
(2) Network settings for the development environment (personal computer)
(a) Network settings for the development environment (personal computer)
CH1
IP address
Subnet mask
* 1 For the Q12DCCPU-V, use an Ethernet cable (straight cable or crossing cable).
For the Q06CCPU-V(-B), use an Ethernet cable (crossing cable).
C Controller module
Figure 6.31 System configuration for 1:1 connection
Set the same network address as that of the C Controller module.
Set the same value.
Network part
Host part
192.168.3.
3
255.255.255.
0
C Controller module
Figure 6.32 Network settings for the development environment (personal computer)
Q12DCCPU-V
Ethernet cable
Development environment
(personal computer)
Network part
Host part
192.168.3.
1
255.255.255.
0
Development environment
(personal computer)
6.6 Network Settings for 1:1 Connection
Q06CCPU-V
Q06CCPU-V-B
*1
Set different values.
6
- 39
1
2
3
4
5
6
7
8