Appendix 11 Functions Added by Version Upgrade
The tables below shows the functions added and the serial numbers of the C Controller
module and software versions of SW3PVC-CCPU that support the functions.
(1) C Controller module
Partial change on C Controller modules
• Supporting the Q12DCCPU-V
• Not supporting the Q06CCPU-V-H01
Supporting more than one QI60 (interrupt module)
Addition of the function that allows access to a buffer memory in an intelligent
function module through an interrupt routine (interrupt program)
Change of the battery backup RAM capacity to 512K bytes.
Addition of the following methods for connecting a GOT.
• Bus connection
• MELSECNET/H connection (PLC to PLC network)
• MELSECNET/10 connection (PLC to PLC network)
• CC-Link IE controller network connection
• CC-Link connection (intelligent device station)
• CC-Link connection (via G4)
• Ethernet connection by the 10BASE-T/100BASE-TX interface of the C
Controller module
Addition of the following methods for connecting GX Developer.
• Ethernet connection by the 10BASE-T/100BASE-TX interface of the C
Controller module
Supporting connection with MX Component
Supporting connection with MELSOFT (GX Developer, GX Works2, and MT
Works2) through Ethernet
Addition of compact flash card as storing destination drive for parameters
Addition of the following devices that can be used like programmable controller
CPU
• Internal relay (M), data register (D)
• Special relay (SM), special register (SD)
Addition of the function that allows execution of an interrupt routine (interrupt
program) in the event of an interrupt from:
• Intelligent function module
• Interrupt module
• Programmable controller CPU (another CPU)
• C Controller module (another CPU)
Supporting CC-Link IE controller network
• Supporting the QJ71GP21-SX and QJ71GP21S-SX
• CC IE Control utility has been added.
Table APPX.26 Functions added to the C Controller module
Function
Appendix 11 Functions Added by Version Upgrade
Q12DCCPU-V
1)Q12DCCPU-V 2)Q06CCPU-V 3)Q06CCPU-V-B
First 5 digits of serial number Software version of
1)
2)
3)
12042 or
later
12042 or
later
12042 or
later
12042 or
later
12042 or
later
12042 or
later
12042 or
later
12042 or
later
12042 or
later
12042 or
later
10012 or
later
: Not related to the serial No. or the software version, : N/A
Q06CCPU-V
Q06CCPU-V-B
SW3PVC-CCPU
Version3.03D or later
(The Ethernet
connection is
Version3.05F or
later)
Version3.05F or later
Version3.05F or later
Version3.05F or later
Version3.05F or later
Version3.05F or later
Version3.05F or later
Version3.02C or later
(To the next page)
APPX
- 45