Access Via Network Modules; User Program Processing Of C Controller Module - Mitsubishi Electric Q12DCCPU-V User Manual

Melsec q series, c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

5

ACCESS VIA NETWORK MODULES

User program processing
(
Operation time)
Suspended
[Check 2: Check if the C Controller system operation meets the system
specifications or not.]
Check if the C Controller system operation meets the system specifications or
not.
Even if the error stated in Check 1 is not detected, normal operation of the C
Controller system must be confirmed.
User program processing in the C Controller module may be suspended when
the following is activated, depending on the operating conditions of the C
Controller system.
• Link device refresh processing
• Interrupt processing
• High-priority task processing (such as the followings)
• Shell command
• Workbench/Tornado connection
• File access
• Mount/unmount of a CompactFlash card
• Ethernet communications
• NFS server communication
• Processing of a bus interface driver
If the user program operation is interrupted longer then its operation time, the
C Controller system specifications may not be satisfied.
If this occurs, take corrective actions according to 5).
Link device
Link device
refresh cycle
refresh cycle
High-priority task
processing
Suspended
Figure 5.22 User program processing of C Controller module
* 1 Functions to transmit with peripheral devices, functions to communicate with an intelligent function
module, etc.
5.3 MELSECNET/H Module Access Function
*1
Link device
refresh cycle
High-priority task
processing
Interrupt
processing
Suspended
Suspended
Suspended
Link device refresh processing
5.3.4 Link device refresh setting
Link device
refresh cycle
High-priority task
processing
Suspended
Suspended
5
- 25
1
2
3
4
5
6
7
8