Appendix 9 Connection with GX Works2/GX Developer
Appendix 9.2 Accessing other stations
POINT
Ethernet is assumed to be the same type of network as CC-Link IE controller
network, MELSECNET/H, or MELSECNET/10.
For this reason, when a combined system of Ethernet, CC-Link IE controller
network, MELSECNET/H, or MELSECNET/10 is used, specify "Other station
(single network)".
4) When "Other station (Single network)" is specified for "Other station", specify
accessed network type
When "Other station (Co-existence network)" is specified for "Other station",
for "Network route" specify the accessed network type
Controller module is connected.
* 1 "C24" and "Ethernet" cannot be specified for the network type.
After specifying the network type, set "Network No.", "Station No." and "Head I/
O No." Setting items vary depending on the network type.
5) Only when "Other station (coexistence network)" is specified for "Other
station", specify the accessed network type for "Co-existence network route".
After specifying the network type, set "Network No.", "Station No." and "Head I/
O No." Setting items vary depending on the network type.
6) If the CPU to be accessed is a multiple CPU system, set the accessed CPU for
"Multiple CPU setting".
For more details, refer to the following.
GX Developer Version 8 Operating Manual
*1
for "Network route".
*1
to which the C