Mitsubishi Electric Q12DCCPU-V User Manual page 496

Melsec q series, c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

16
TROUBLESHOOTING
16.2.14
If the endian format (memory layout) of the user program is different from that of the C
Controller module, an error will occur in the following operation:
An error message is displayed as shown below when the endian format does not match.
If any of the shown messages appears, take corrective actions referring to (2) in this
section.
(1) Error messages indicating the endian format mismatch between the
16
- 25
16.2 Troubleshooting
16.2.14 When an error occurred during user program download or ld command execution
When an error occurred during user program download or ld
command execution
• Downloading a user program to a C Controller module
• Executing a user program with the ld command
user program and the C Controller module
(a) For the Q12DCCPU-V
1) When downloading a user program to a C Controller module
Failed to load "..xxx/SH7750gnu/Demo1.out on "yyyyyyyy@zzzzz:SH-4A"
2) When executing a user program with the ld command
ld(1,0,"/CF/Demo1.out")
ld(): error loading file (errno = 0x610001).
value = 0 = 0x0
<errno detail>
printErrno 0x610001
errno = 0x610001 : S_loadElfLib_HDR_READ.
value = 0 = 0x0
Q12DCCPU-V
Figure 16.14 Error message
Figure 16.15 Error message
Q06CCPU-V
Q06CCPU-V-B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw3pvc-ccpu-eQ06ccpu-vQ06ccpu-v-b

Table of Contents