Parameter Settings Related to Position Deviation between Axes Overflow Detection
These parameters set the position deviation between axes allowed for the machine or product.
Position Deviation between Axes Overflow Warning Level
Pn669
Setting Range
All Axes
Position Deviation between Axes Overflow Alarm Level
Pn66A
Setting Range
All Axes
1,073,741,823*
*
If the setting value of Pn66A is 0, the position deviation between axes overflow alarm and warning are disabled.
Note: Adjust the settings of Pn669 and Pn66A after setting the origin of the machine. If the values of Pn669 and
Pn66A are decreased before the origin of the machine is set, a warning or alarm may occur when the origin is
set.
5.2 Parameter Settings Related to Position Deviation between Axes Overflow Detection
Setting Unit
10 to 100
%
Setting Unit
0 to
Reference unit
Default Setting
When Enabled
100
Immediately
Default Setting
When Enabled
5,242,880
Immediately
Po ition
Classification
Setup
Po ition
Classification
Setup
5-3
5