126 en | Keypads
5.3.3

Keyfob Panic Options

Default: Panic response disabled
Selections:
The keyfob panic response is enabled or disabled globally. The outputs activate for the Burg
Time configured in their respective areas. If the Alarm Bell is active, silencing the alarm logs a
Cancel event. No alarm abort window is supported.
When an audible panic response is generated, a Burg Alarm is indicated and sounded on all
keypads that have scope over the areas where the alarm bell is active. The control panel logs a
Keyfob Panic Alarm event. The user number associated with the keyfob is logged with the
event. No restoral event is logged.
Keyfob panic alarm events have a configuration option enabling or disabling their reporting by
route group. This option is available only from RPS in PANEL WIDE PARAMETERS > Report
Routing. This option controls the reporting of both Keypad Panic Alarms and Keyfob Panic
Alarms.
When a silent panic response is generated, the control panel activates the Area Wide Output >
Duress Output in each area that the keyfob user has authority. The outputs activate for the
Burg Time configured in their respective areas.
If the duress output is active, silencing the alarm logs a Cancel event. No alarm abort window
is supported. When a silent panic response is generated, there is no indication or sound on
any keypad. When a silent panic response is generated, the control panel logs a Key Fob Silent
Alarm event. The user number associated with the keyfob is logged with the event. No restoral
event is logged for a keyfob Silent Alarm.
Keyfob silent alarm events have a configuration option, separate from the keyfob panic alarms,
enabling or disabling their reporting by route group. This option is available only from RPS in
PANEL WIDE PARAMETERS > Report Routing. This option controls the reporting of both
Keypad Silent Alarms and keyfob Silent Alarms.
RPS Menu Location
Keypads > Wireless keyfob > keyfob Panic Options
2017.03 | 09 | F.01U.303.998
Panic response disabled - the control panel ignores all panic button presses from every
keyfob.
Audible panic response enabled - when a panic button is pressed on any keyfob the
control panel activates an audible tone at the keypads and activates the Alarm Bell
output.
Silent panic response enabled - when a panic button is pressed on any keyfob the control
panel activates the Silent Alarm output and keypads remain silent.