Early Ambush; Fire Time - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
If the area is already in an alarm event, the first passcode entry silences the alarm. The second
passcode entry disarms the area.
If the second passcode is entered using a different keypad than the first passcode, the second
keypad displays a warning that the Two Man Rule is already running. Enter both passcodes
using the same keypad.
The area scope that is disarmed is determined by the first passcode that starts the Two Man
Rule?, page 98. A single area keypad (with Scope, page 111) is required for this feature.
You can create a custom function that will disarm the area using passcode disarm.
Set this parameter to Yes in facilities that require a higher level of security to gain access to
the secured area. For example, a bank might enable this parameter to gain access to the vault.
If this parameter is enabled, set the Scope, page 111 parameter for keypads in the affected
areas to "Area Wide."
You should not set Two Man Rule to Yes in an area that also has Early Ambush?, page 99 set
to Yes.
This function only works when you use passcode disarm.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Two Man Rule
4.1.14

Early Ambush?

Default: No
Selections:
This parameter requires two valid passcodes to disarm the area within the time limit set in the
Early Ambush Time, page 78 parameter.
Notice!
To comply with SIA CP-01 False Alarm Reduction, set this parameter to No for all enabled
areas. Refer to SIA CP-01 Verification for more information.
The first passcode entry disarms the area, and the second passcode entry validates the disarm
command. The passcodes can be entered from any two keypads in the area. It is
recommended that you use this parameter when disarming from an All On area, or during the
entry delay period for All On.
You can create a custom function that will disarm the area using passcode disarm. If the
second passcode is not entered before the Early Ambush Time, page 78 ends, the control panel
generates a duress event based on the primary user. You should not set Early Ambush?, page
99 to Yes in an area that also has Two Man Rule?, page 98 set to Yes.
This function only works when you use passcode disarm.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Early Ambush
4.1.15

Fire Time

Default: 6
Selections: 1 to 90 (minutes) (in one minute increments)
This parameter sets the length of time in minutes the bell rings for fire alarm points.
Bosch Security Systems, Inc.
Yes - two valid passcodes are required to disarm the area within the time limit set in the
Early Ambush Time, page 78 parameter.
No - one passcode with a valid authority level can disarm the area.
Program Entry Guide
Area Wide Parameters | en
2017.03 | 09 | F.01U.303.998