136 en | Output Parameters
When an area's arming state switches from All On (either delay or instant) to Part On or
Disarmed, the output number configured here activates.
When an area's arming state switches from Part On or Disarmed to All On (either delay or
instant), the output number configured here de-activates.
If the same output number is configured in more than one area's Area Off Output, the output
will only activate when the first area is no longer armed All On. If the same output number is
configured in more than one area's Area Off Output, the output will only de-activate if all
area's using that same output number are armed All On.
The Area Off Output is also affected by the Early Area Armed Output, page 81. When the Early
Area Armed Output is set to No,the Area Off Output does not activate until the end of exit
delay. When the Early Area Armed Output is set to Yes, the Area Off Output de-activates as
soon as exit delay starts and the area is armed All On.
Note: if the All On- No Exit, page 106 option is set to Yes and the area switches to Part On at
the end of exit delay, the Area Off Output will activate at that time.
Simply starting entry delay does not affect the state of the output configured in Area Off.
RPS Menu Location
Output Parameters > Area Wide Outputs > Area Off
8.1.9

Area Fault

Default: 0
Selections:
The output activates whenever a Part On, Interior or Interior Follower point is faulted. The
output remains activated until all perimeter and interior points in the area are normal.
Keyswitch area fault status with LED's: Use a B308 module and connect an LED to illuminate
when this output is activated indicating that the area is not ready to arm.
Assign a unique output number for each area.
RPS Menu Location
Output Parameters > Area Wide Outputs > Area Fault
8.1.10

Duress Output

Default: 0
Selections:
The output activates when a duress event is generated from a keypad assigned to the area.
Burg Time must have a bell period programmed and Duress Enable, page 96 must be set to Yes.
This output activates "steady" regardless of bell pattern and remains active until the bell time
expires.
You can assign a different output number for the Duress Output each area.
RPS Menu Location
Output Parameters > Area Wide Outputs > Duress Output
8.1.11

Part On Fault

Default: 0
Selections:
2017.03 | 09 | F.01U.303.998
B9512G: 0 to 599
B8512G: 0 to 99
B9512G: 0 to 599
B8512G: 0 to 99
B9512G: 0 to 599
B8512G: 0 to 99