Control Panel
Notice!
Authority Level 15 is reserved for the Service Passcode (User 0). You cannot change any
settings in the Authority Level 15 column.
RPS Menu Location
User Configuration > Authority Levels > Security Level
9.4.46

Disarm Level

Default:
Authority Levels 1-5: Disarm (D)
Authority Levels 6-15: No Disarm Rights (-)
Selections:
When the user presents a card door reader, the panel checks the Access Level and enables
area disarm functions as programmed.
Opening and Closing reports are sent to the central station receiver if programmed.
For more information on programming this prompt for a Shared area, see the Access Control
Readers Assigned to the Shared Area paragraph for the Area Type, page 96 prompt in Area
Parameters.
Notice!
Burglar bells silenced when user presents token/card
Burglar bells are silenced in the local area when a user disarms with a token/card, or presents
the token/card during an alarm. The user must use a passcode to silence a fire bell. Cancel
reports are sent after a valid passcode or token/card has silenced the bell.
Notice!
Authority Level 15 reserved
Authority Level 15 is reserved for the Service Passcode (User 0). You cannot change any
settings in the Authority Level 15 column.
RPS Menu Location
User Configuration > Authority Levels > Disarm Level
9.4.47

Function Level

Default:
Authority Level 1: Disarmed (D)
Authority Levels 2-15: No Function Level (-)
Selections:
Bosch Security Systems, Inc.
All or Part On to Part On Instant (I): Users change the All On state and Part On state to
[Part On INSTANT]. The armed state does not change in other areas, and the armed state
does not change if the area is already in the Part On instant or disarmed state. User must
have Access Level for All On (A) state.
Disarm (D): Users change the local area's All On state and Part On state to the disarm
state. User must have Access Level for All On (A) or Part On (P) state. All areas within the
scope of the keypad assigned to the KP# Scope in the Access handler and areas to which
the user has disarm rights disarm as programmed.
No Disarm Rights (-): Users do not have disarm rights in this area.
All On (A): Activate the custom function assigned to the door in this area when the area is
All On or Part On.
Program Entry Guide