Control Panel
Setting this parameter to Yes for Cross Point Timer, page 181 can cause missed cross-point
alarms. For example, if Points 1 and 2 are programmed as Cross Points and Point 1 is
bypassed or force armed, Point 2 is not able to generate an ALARM CROSS POINT event.
However, Point 2 can generate an UNVERIFIED or ALARM event depending on how the point
was tripped.
A point can be bypassed at the keypad using the BYPASS? function.
RPS Menu Location
Points > Point Profiles > Bypassable
10.3.22

Swinger Bypass

Default: No
Selections:
Use this parameter to allow the control panel to automatically bypass a point that erroneously
reports a pre-determined number of  alarm or trouble events within the same arm cycle.
The control panel reports a Swinger Bypass when the Swinger Bypass Count, page 80 is
reached and Report Bypass at Occurrence, page 197 is set to Yes. If the point has a partial
count (less than the Swinger Bypass Count number of events an hour), the count is reset to
zero.
Bypassable, page 196 does not need to be set to Yes for swinger bypass to work.
A swinger-shunted point returns to the system if Bypass Returnable, page 196 is set to Yes. If
not, return the point to the system as described in Bypass Returnable.
RPS Menu Location
Points > Point Indexes > Swinger Bypass
10.3.23

Report Bypass at Occurrence

Default: No
Selections:
This parameter allows a point to generate a COMMAND BYPASS report as soon as a user
bypasses the point from the keypad.
Enable this parameter for all bypassable 24-hour points. You can also report a bypassed point
at the time the area is armed. Refer to Defer Bypass Report, page 197.
RPS Menu Location
Points > Point Indexes > Report Bypass at Occurrence
10.3.24

Defer Bypass Report

Default: No
Selections:
Use this parameter to prevent points that are bypassed by the user from reporting until the
area is armed.
Once the area is armed, the bypassed points as well as any point being bypassed during the
arming sequence report as POINT BYPASS along with the closing report.
Bosch Security Systems, Inc.
Yes  Enable Swinger Bypass for this point.
No   Disable Swinger Bypass for this point.
Yes:  Send a report at the time that the point is bypassed.
No:   Do not send a report at the time the point is bypassed.
Yes. Send a report with the closing report instead of when the point is bypassed by a
user.
No. Do not defer bypass reports.
Program Entry Guide
Points | en 197