Account O/C; Area O/C; Disable O/C In Window - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
4.1.22

Account O/C

Default: No
Selections:
This parameter determines if account opening and closing reports are generated by this area.
Set this parameter the same for all areas in the account.
An account opening report is generated when the first area in an account is opened
(disarmed). After the account opening report is sent, disarming other areas in the account
does not generate another account opening report. An account closing report is generated
only when the last area in an account is closed (armed). Account opening and closing reports
do not contain any area information.
If an account opening or closing is generated while an opening or closing window for this area
is in effect, and Disable O/C in Window, page 103 is set to Yes, the report is not sent. Bosch
recommends that all areas sharing the same account number use the same opening and
closing window times.
Note: Account numbers are sent over the network to the central station receiver.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Account O/C
4.1.23

Area O/C

Default: Yes
Selections:
This parameter determines if the area number and the account number are sent upon arming
and disarming.
As long as Account O/C, page 103 is set to No, the account number is sent when arming this
area individually. If Acct O/C is set to Yes, all areas with the same account number must also
be armed. An area opening report is generated when each individual area is opened
(disarmed). An area closing report is generated when each individual area is closed (armed).
Do not set this parameter to Yes if the control panel sends reports to an automation system
that cannot interpret multiple area opening/closing reports.
Opening/Closing Reports are only sent for users with Authority Levels, page 158 assigned as
follows:
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Area O/C
4.1.24

Disable O/C in Window

Default: Yes
Selections:
Bosch Security Systems, Inc.
Yes - send opening and closing reports by account. Use this selection if the control panel
sends reports to an automation system that cannot interpret multiple area opening/
closing reports.
No - do not send opening and closing reports by account.
Yes - include the area number and generate opening and closing reports for this area
when it is armed.
No - do not include the area number or generate opening and closing reports for this
area.
Ready to Arm: Area Open/Close = E
Not Ready to Arm (Force Arm/Bypass Arm): Restricted Open/Close = E
Part On Arm: Part On Open/Close = E