116 en | Keypads
5.1.15

Entry Tone

Default: Yes (for all KP addresses)
Selections:
This parameter determines whether this keypad or any keypad with the same address setting
sounds the entry delay tone.
Any delay point within the area scope of this keypad initiates the entry sequence.
This parameter allows you to manage the tone by keypad. Entry tone can also be turned off
when programming Entry Tone Off in Point Index.
Assign two keypads to the same area to have one sound the tone while the other does not.
Set this parameter to Yes for UL installations.
RPS Menu Location
Keypads > Keypad Assignments > Entry Tone
Additional Resource
Entry Tone Off, page 191
5.1.16

Exit Tone

Default: Yes (for all KP addresses)
Selections:
This parameter determines whether this keypad or any keypad with the same address setting
sounds the exit delay tone during the delay arming of an area.
Any keypad that has a scope to arm this area can initiate the exit tone sequence.
This parameter allows you to manage the tone by keypad. Exit tone can also be turned off
when programming your Exit Tone in Area Parameters.
Assign two keypads to the same area to have one sound the tone while the other does not.
RPS Menu Location
Keypads > Keypad Assignments > Exit Tone
5.1.17

Arm Area Warning Tone

Default: Yes (for all KP addresses)
Selections:
Use this parameter to determine whether this keypad sounds an audible tone and displays a
warning on the keypad when a closing window has activated.
RPS Menu Location
Keypads > Keypad Assignments > Arm Area Warning Tone
5.1.18

Close Door Warning Tone

Default: Yes (for all KP addresses)
Selections:
2017.03 | 09 | F.01U.303.998
Yes: This keypad sounds entry tones.
No: This keypad does not sound entry tones.
Yes - this keypad sounds exit tones.
No - this keypad does not sound exit tones.
Yes - this keypad activates a tone and warning display.
No - this keypad does not activate a tone or warning display.
Yes - this keypad activates a tone and warning display.
No - this keypad does not activate a tone or warning display.