Inactivity Timeout (Min.); Reporting Delay For Low Signal Strength (Sec.) - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
RPS Menu Location
Panel Wide Parameters > Cellular Plug-in Module > Session Keep Alive PeriodKeep Alive Period
3.3.3

Inactivity Timeout (min.)

Notice!
Important configuration information for cellular communication
Refer to Configuring for Cellular Service, page 280 for an overview and configuration
information.
Default: 0
Selections: 0 to 1000 (minutes)
This parameter specifies the time before the control panel will disconnect a session with no
data traffic. This parameter is pre-configured for optimal performance. Leave at the default
setting. Default settings should only be changed for high security UL1610 commercial listed
installations requiring low signal notification.
RPS Menu Location
Panel Wide Parameters > Cellular Plug-in Module > Inactivity Timeout
3.3.4

Reporting Delay for Low Signal Strength (sec.)

Notice!
Important configuration information for cellular communication
Refer to Configuring for Cellular Service, page 280 for an overview and configuration
information.
Default: 0
Selections: 0-3600 (seconds)
Notice!
UL Requirement
To meet UL requirements, the entry for this parameter should not exceed 200 seconds.
The control panel creates a Cellular Low Signal event when the signal strength is below the
"unacceptable" threshold (indicated by the red LED) for the number of seconds specified in
this Reporting Delay for Low Signal Strength parameter. (Low signal is defined as 80% of the
measurements taken during the time period are below the threshold).
The control panel creates a Cellular Low Signal Restoral event when the signal strength is
above the "good" threshold (indicated by the green LED) for the number of seconds specified
in this Reporting Delay for Low Signal Strength parameter. (Good signal is defined as 80% of
the measurements taken during the time period are above the threshold).
RPS Menu Location
Panel Wide Parameters > Cellular Plug-in Module > Reporting Delay for Low Signal Strength
Bosch Security Systems, Inc.
0 - Disabled. Panel does not verify the connection is active.
1 to 1000 - Enabled. Panel verifies an active connection exists.
0 - Disabled.
1 to 3600 - seconds of delay before Cellular Low Signal event.