80
en | Panel Wide Parameters
Notice!
Passcode Length Changes via the SIA CP-01 Verification Parameter
RPS displays the following message dialog: "This operation will cause the Passcode Length to
be disabled, all other parameters previously updated in the SIA Compliance Warning window
will be saved, SIA CP-01 Verification parameter will be set to No and previously existing RPS
passcode data will be stored. Are you sure you want to continue?"
Notice!
Incorrect Passcodes
RPS displays the following message dialog: "This operation will cause the Passcode Length to
be disabled, SIA CP-01 Verification parameter will be set to No and the control panel's
passcode data will be stored. Are you sure you want to continue?"
Notice!
Passcode Length Change during Send/Receive
RPS displays the following message dialog: "This operation will cause the Passcode Length to
be disabled, all other parameters previously updated in the SIA Compliance Warning window
will be saved, SIA CP-01 Verification parameter will be set to No and the control panel's
passcode data will be stored. Are you sure you want to continue? "
Similar and Duplicate Passcodes
For example, if you enter "478123" as a passcode for User 2, and "478321" as a passcode for
User 3, and you set Passcode Length to three digits, the passcodes for Users 2 and 3 appear
in the Duplicate/Duress Passcodes field because both of these passcodes share "478" as the
first three digits. If Passcode Length were changed from four digits to three digits, all of these
passcodes would become duplicate passcodes of "478."
RPS Menu Location
Panel Wide Parameters > Miscellaneous > Passcode Length
3.15.15

Swinger Bypass Count

Default: 2
Selections: 1 to 4
This parameter sets the maximum number of faults allowed on a point within an hour before it
is automatically bypassed.
Notice!
To comply with SIA CP-01 False Alarm Reduction, set this parameter to either 1 or 2. Refer to
SIA CP-01 Verification for more information.
When upgrading a non-control panel account to a control panel account, RPS forces the
default to 4. Use this value for backward compatibility with previous control panel operation.
RPS Menu Location
Panel Wide Parameters > Miscellaneous > Swinger Bypass Count
2017.03 | 09 | F.01U.303.998
Similar Passcodes: If the passcode you enter resembles another existing passcode, the
existing passcode appears in the Existing Similar Passcodes field.
Duplicate Passcodes: If you enter a passcode that matches an existing passcode, the
existing passcodes appear in the Duplicate/Duress Passcodes field. Passcode matches
are based on duplicate entries with the length set to the lowest value that complies with
SIA CP-01 (3).
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B8512gB8512g-eB9512g-e

Table of Contents