Sms Phone # / Email Address; User Language; Method - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

86
en | Panel Wide Parameters
3.16.2

SMS Phone # / email address

Default: Blank
Selections:  Up to 255 alphanumeric characters
This parameter specifies either the destination phone number that will receive an SMS text
notification or the email address that will receive an email message.
SMS Phone #
The control panel sends personal notifications to a cellular device when the programmed
destination is a valid cellular telephone number containing only numbers 0-9. Hyphens are not
allowed.
Email Address
The control panel sends personal notifications to email accounts when the programmed
destination is a valid email address. An email address is considered valid if it is copied
verbatim from an internet email provider.
Note: if the destination is neither a valid phone nor valid email, no message will be sent and an
SMS send error will be logged.
RPS Menu Location
Panel Wide Parameters > Personal Notification > Personal Notification Destinations > SMS
Phone #/email address
3.16.3

User Language

Default: 1:(language programmed as first language in Panel Data window)
Selections:
This selection determines the language that the personal notification message is sent in.
First and Second languages are programmed during panel account setup in the New Panel
Data window. Supported languages include English, Spanish, French and Portuguese.
RPS Menu Location
Panel Wide Parameters > Personal Notification > Personal Notifications Destinations > User
Language
3.16.4

Method

Default: Plug in Cellular Sms
Selections:
This selection will determine if an SMS (text message) or email is sent to the desired Personal
Notification destination and it determines which device will be used to route the message.
RPS Menu Location
Panel Wide Parameters > Personal Notification > Personal Notifications Destinations > Method
2017.03 | 09 | F.01U.303.998
1:(first language)
2:(second language)
None
Plug-in Cellular SMS - may be selected if you have a B44x plug-in cellular module.
Plug-in Cellular Email - may be selected if you have a B44x plug-in cellular module.
Bus Device Address 1 Cellular SMS. May be selected if you have a B450 v2 module.
Bus Device Address 1 Email - may be selected if you have a B450 v2, or a B426 v3
module.
On-board Ethernet Email - may be selected if your connection is on-board IP.
Bus Device Address 2 Cellular SMS - may be selected if you have a B450 v2 module.
Bus Device Address 2 Email - may be selected if you have a B450 v2, or a B426 v3
module.
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B8512gB8512g-eB9512g-e

Table of Contents